Search
Skip to Search Results- 34Carey, Jason P.
- 15Major, Paul W.
- 13Melenka, Garrett W.
- 9Nobes, David S.
- 5Heo, Giseon
- 5Toogood, Roger W.
- 32Mechanical Engineering, Department of
- 30Mechanical Engineering, Department of/Journal Articles (Mechanical Engineering)
- 2WISEST Summer Research Program
- 2WISEST Summer Research Program/WISEST Research Posters
- 2Mechanical Engineering, Department of/Progress in Canadian Mechanical Engineering, Volume 5
- 1Graduate and Postdoctoral Studies (GPS), Faculty of
-
An investigation into the mechanical characteristics of select self-ligated brackets at a series of clinically relevant maximum torquing angles: Loading and unloading curves and bracket deformation
Download2011
Nobes, David S., Major, Paul W., Melenka, Garrett W., Major, Thomas, Carey, Jason P.
Edgewise orthodontic treatment utilizes a force couple in order to achieve labial–lingual tooth angulation. Two self-ligating brackets (Damon Q and Speed) were examined across a range of clinically relevant torques in order to assess the loading and unloading curves and bracket deformation. A...
-
2013
Adeeb, Samer, El-Rich, Marwan, Lewicke, Justin, Carey, Jason P., Schofield, Jonathon, Parent, Eric
Sit-to-stand transfer (STS) is a common yet critical prerequisite for many daily tasks. Literature conducted on healthy STS often assume the body to behave symmetrically across the left and right side; yet only a few studies have been conducted to investigate this supposition. These studies have...
-
Comparison of Deformation and Torque Expression of the Orthos and Orthos Ti Bracket Systems
Download2011
Major, Paul W., Melenka, Garrett W., Carey, Jason P., Nobes, David S., Heo, Giseon, Lacoursiere, Ryan A.
Orthodontic torque expression is the result of axial rotation of rectangular archwires within a rectangular bracket slot. This study investigates the effect of bracket material on torque expression. Torque exerted by a rotating archwire on each bracket will be measured as well as the relative...
-
Comparison of high- and low-calibre ice skaters stride time and stride length on a synthetic ice surface
Download2022-06-01
Khandan, Aminreza, Fathian, Ramin, Carey, Jason P., Rouhani, Hossein
Conference abstract. Part of the Proceedings of the Canadian Society for Mechanical Engineering International Congress 2022.
-
2013
Major, Paul W., Melenka, Garrett W., Nobes, David S., Carey, Jason P.
The design and testing of an orthodontic torque simulator that reproduces the effect of archwire rotation on orthodontic brackets is described. This unique device is capable of simultaneously measuring the deformation and loads applied to an orthodontic bracket due to archwire rotation. Archwire...
-
2007
Kerstein, Robert B., Carey, Jason P., Craig, Mark, Radke, John
Articulating paper mark size has been widely accepted in the dental community to be descriptive of occlusal load. The objective of this study is to determine if any direct relationship exists between articulating paper mark area and applied occlusal load. A uniaxial testing machine repeatedly...
-
2015
Heo, Giseon, Major, Paul W., Melenka, Garrett W., Carey, Jason P., Romanyk, Dan R., Toogood, Roger W., Fathimani, Maryam
Background The primary objective of this study was to develop a computer-controlled three-dimensional friction measuring system, the orthodontic friction simulator (OFS). A clinically-based in vitro experiment considering wet and dry friction for conventionally and self-ligated brackets is...
-
Effect of Ligation Method on Maxillary Arch Force / Moment Systems for a Simulated Lingual Incisor Malalignment
Download2014
Romanyk, Dan L., Major, Paul W., Seru, Surbhi, Toogood, Roger W., Carey, Jason P.
Introduction: The objectives of this study were to determine whether there is a difference in the magnitude of forces and moments produced by elastic ligation when compared to passive ligation, and whether these forces and moments propagate differently along the arch for the two ligation types. A...