Fall 2009
Resonant microcantilevers are promising transducers for bacteria detection because of their high sensitivities. Surface stress and mass from adsorbates affect the resonant frequency. We developed a novel method for decoupling the frequency contributions of a change in mass and surface stress on a...
-
Spring 2010
The procedure for milling micrometre scale cantilevers of lutetium iron garnet using a focused ion beam microscope was developed. The infrastructure to study these cantilevers using rotational hysteresis loops and ferromagnetic resonance experiments was set up. The cantilevers were shown to...
-
Fall 2010
The scanning tunneling microscope (STM) based on quantum tunneling can attain atomic-scale spatial resolution and help elucidate a wealth of phenomena in the microscopic world. However a limitation in scanning tunneling microscopy is the low temporal resolution due to readout circuit frequency...
-
Metallic thin films for NEMS/MEMS: from fundamental behaviour to microstructural design and fabrication
DownloadFall 2011
The main focus of this thesis is the study of thin metal films in microelectromechanical/nanoelectromechanical systems (MEMS/NEMS), ranging from application to fundamental behaviour. The use of metallic structural components is desirable since they are electrically conductive, optically reflective...
-
Fall 2011
High aspect ratio microelectromechanical structures have been found, in the literature, to collapse due to capillary forces of liquids. In this dissertation, mathematical models are developed to study (i) the collapse of a microstructure represented by a double cantilevered beam (DCB) with a free...
-
An examination of linking and blocking procedures for use in deflection cantilever array-based protein detection
DownloadFall 2011
In this project common linking and blocking procedures were examined for use in multiplexed deflection cantilever array-based detection of proteins. A human interferon gamma (INF-γ) enzyme-linked immunosorbent assay (ELISA) kit was used to evaluate the effectiveness of the linking and blocking...
-
Fall 2013
This thesis outlines the development of two platforms for integrating microfabricated sensors with high pressure feedthroughs for application in hostile high temperature high pressure environments. An application in oil well production logging is explored and two sensors were implemented with...
-
Fall 2013
The continuing interest in Lab-on-a-Chip technologies and Point-of-Care diagnostics systems is driving the development of supporting components for microfluidic regulation. Optimally the microfluidic regulation components would operate cyclically with a minimum input power, could be precisely...
-
Utilization of Semiconductors Piezoresistive Properties in Mechanical Strain Measurements under Varying Temperature Conditions for Structural Health Monitoring Applications
DownloadSpring 2013
Strain gauges have been powerful tools in experimental stress analysis. This importance is expected to continue, even though other means of strain measurement are continually introduced to the market. The strain gauge is a simple device that can be easily installed to measure mechanical strain....
-
Spring 2013
An alternative method of manipulating fragile MEMS devices during fabrication has been developed. A specialized manual or robotic end effector utilizing a gecko inspired adhesive can replace the slow and costly manual tweezers used by the MEMS foundry Micralyne Inc. Improving the adhesive...