This decommissioned ERA site remains active temporarily to support our final migration steps to https://ualberta.scholaris.ca, ERA's new home. All new collections and items, including Spring 2025 theses, are at that site. For assistance, please contact erahelp@ualberta.ca.
Search
Skip to Search Results- 35Kulak, Geoffrey L.
- 33Grondin, Gilbert Y.
- 21Simmonds, S. H.
- 18Driver, Robert G.
- 16Elwi, Alaa-Eldin A.
- 16MacGregor, James G. (James Grierson), 1934-
- 260Graduate and Postdoctoral Studies (GPS), Faculty of
- 260Graduate and Postdoctoral Studies (GPS), Faculty of/Theses and Dissertations
- 247Civil and Environmental Engineering, Department of
- 247Civil and Environmental Engineering, Department of/Structural Engineering Reports
- 22Computing Science, Department of
- 14Computing Science, Department of/Technical Reports (Computing Science)
- 281Report
- 260Thesis
- 18Article (Published)
- 7Conference/Workshop Presentation
- 4Article (Draft / Submitted)
- 2Conference/Workshop Poster
- 163Department of Civil and Environmental Engineering
- 16Department of Chemistry
- 15Department of Mechanical Engineering
- 10Department of Chemical and Materials Engineering
- 9Department of Civil Engineering
- 9Department of Electrical and Computer Engineering
- 13Adeeb, Samer (Civil and Environmental Engineering)
- 9Driver, Robert (Civil and Environmental Engineering)
- 9Tomlinson, Douglas (Civil and Environmental Engineering)
- 8Bindiganavile, Vivek (Civil and Environmental Engineering)
- 7Cruz-Noguez, Carlos (Civil and Environmental Engineering)
- 7El-Rich, Marwan (Civil and Environmental Engineering)
Results for "Structural Engineering Reports"
-
Fall 2023
response with the focus on column force and BRB strain demands. A combination of mechanics principles, structural analysis techniques, numerical simulation and experimental testing is used to achieve these objectives. A full-scale test program is conducted on a two-tiered BRBF to verify experimentally
-
Fall 2023
Multi-tiered braced frames are commonly used as the lateral load-resisting system of tall single-storey buildings or tall storeys of multi-storey buildings. This framing system divides the frame or storey height into multiple bracing panels, resulting in more economical member sizes and practical...
-
Spring 2012
Combining steel fiber reinforced concrete (SFRC) and high strength longitudinal reinforcement in a structural member creates the potential for increased strength and durability compared to conventional reinforced concrete members. There is however limited research into the structural behaviour of
behaviour of structural slabs were examined through the testing of six large scale specimens in three point bending. The overall member height and longitudinal reinforcement ratio were the primary variables of interest while the shear span to effective depth ratio was held constant at 3. No transverse
-
Shear Behaviour of Concrete Slabs and Beams Reinforced with High-Performance ASTM A1035 Steel
DownloadFall 2013
corrosion. Thus there is increasing interest in the use of ASTM A1035 steel to reduce life-cycle costs for new concrete structures. However, the lack of a well defined yield point for this material requires careful assessment of structural design models to ensure that they accurately account for influences
-
Fall 2012
coarse aggregate. The fractured surface of the specimens revealed that in the lightweight and high strength mixes, cleavage was through the aggregates. A total of 18 structural SFRC specimens were designed and constructed to capture the behavior of shear-critical SFRC members. The specimens contained
-
Shear Strength of Partially Grouted (PG) Masonry Shear Walls: Experimental and Analytical Studies
DownloadFall 2023
When subjected to in-plane loads, the shear behaviour of partially grouted (PG) masonry shear walls is complex due to the heterogeneous and anisotropic nature of the masonry materials and the nonlinear interactions among their constituents. For instance, insufficient shear strength will lead to a...
-
Simplified seismic design methods for low-ductile steel multi-tiered concentrically braced frames
DownloadFall 2020
Multi-Tiered Concentrically Braced Frames (MT-CBFs) represent a bracing configuration where two or more concentric braced panels are stacked between the storey levels in multi-storey buildings or between the ground and roof levels in single-storey buildings such as sports facilities, airplane...
-
Standardization and Testing of Embedded Plates for Design, Fabrication, and Construction Economy
DownloadSpring 2021
Embedded plates are commonly used to facilitate connecting structural steel members to reinforced concrete building elements such as walls and columns. Due to a lack of readily available industry-wide standard embedded plate designs, embedded plates are often custom designed for each project. This
-
Statistical Prediction Methods for the In-Plane Shear Strength of Partially Grouted Masonry Walls
DownloadSpring 2021
The behaviour of partially grouted masonry shear walls is complex due to their anisotropic nature and the nonlinear interactions between blocks, mortar, grouted cells, ungrouted cells and steel reinforcement. Currently available code- and research-based shear strength equations give highly...
-
Fall 2013
The objective of this research is to develop design methods for steel plate shear wall in low and moderate seismic regions, and to examine its performance under accidental blast. Different practical details are investigated to reduce the force demands on the boundary frame of the wall system and...