Search
Skip to Search Results- 10Carbohydrates
- 7Mass-spectrometry
- 4Affinity
- 4Electrospray ionization mass spectrometry
- 4Lipids
- 4Proteins
-
Screening carbohydrate libraries for protein interactions using the direct ESI-MS assay: Applications to libraries of unknown concentration
Download2014
El-Hawiet, Amr, Klassen, John S., Kitova, Elena N.
A semiquantitative electrospray ionization mass spectrometry (ESI-MS) binding assay suitable for analyzing mixtures of oligosaccharides, at unknown concentrations, for interactions with target proteins is described. The assay relies on the differences in the ratio of the relative abundances of...
-
Screening carbohydrate libraries for protein interactions using the direct ESI-MS assay: Applications to libraries of unknown concentration
Download2014
El-Hawiet, Amr, Klassen, John S., Kitova, Elena N.
A semiquantitative electrospray ionization mass spectrometry (ESI-MS) binding assay suitable for analyzing mixtures of oligosaccharides, at unknown concentrations, for interactions with target proteins is described. The assay relies on the differences in the ratio of the relative abundances of...
-
Structure and stability of carbohydrate-lipid interactions: Methylmannose polysaccharide-fatty acid complexes
Download2016
Klassen, John S., Siuda, Iwona, Renaud, Justin, Tieleman, D. Peter, Kitova, Elena N., Liu, Lan, Mayer, Paul M., Richards, Michele R., Lowary, Todd L.
We report a detailed study of the structure and stability of carbohydrate–lipid interactions. Complexes of a methylmannose polysaccharide (MMP) derivative and fatty acids (FAs) served as model systems. The dependence of solution affinities and gas-phase dissociation activation energies (Ea) on FA...
-
Structure and stability of carbohydrate-lipid interactions: Methylmannose polysaccharide-fatty acid complexes
Download2016
Mayer, Paul M., Richards, Michele R., Lowary, Todd L., Renaud, Justin, Klassen, John S., Tieleman, D. Peter, Kitova, Elena N., Liu, Lan, Siuda, Iwona
We report a detailed study of the structure and stability of carbohydrate–lipid interactions. Complexes of a methylmannose polysaccharide (MMP) derivative and fatty acids (FAs) served as model systems. The dependence of solution affinities and gas-phase dissociation activation energies (Ea) on FA...
-
Unique Ion Filter: A data reduction tool for GC/MS data preprocessing prior to chemometric analysis
Download2014
Harynuk, James, Adutwum, Lawrence A.
Using raw GC/MS data as the X-block for chemometric modeling has the potential to provide better classification models for complex samples when compared to using the total ion current (TIC), extracted ion chromatograms/profiles (EIC/EIP), or integrated peak tables. However, the abundance of raw...