Spring 2011
Steel plate shear walls have typically been analyzed using quasi static and monotonic pushover analysis; however, dynamic excitations during an earthquake elicit different behaviour from the structure due to the nature of the loading. This report outlines the design and analysis of a steel plate...
-
2009
Stankevicius, Joseph, Kulak, Geoffrey L., Georg, Josi, Grondin, Gilbert Y.
Structural engineering report SER 268 | SER-ID SER268