Search
Skip to Search Results- 6Carey, Jason P.
- 6Melenka, Garrett W.
- 5Nobes, David S.
- 4Major, Paul W.
- 2Lacoursiere, Ryan A.
- 1Heo, Giseon
- 6Deformation
- 3Digital Image Correlation
- 2Archwire
- 2Bracket
- 2Digital image correlation
- 2Orthodontic bracket
-
Comparison of Deformation and Torque Expression of the Orthos and Orthos Ti Bracket Systems
Download2011
Major, Paul W., Melenka, Garrett W., Carey, Jason P., Nobes, David S., Heo, Giseon, Lacoursiere, Ryan A.
Orthodontic torque expression is the result of axial rotation of rectangular archwires within a rectangular bracket slot. This study investigates the effect of bracket material on torque expression. Torque exerted by a rotating archwire on each bracket will be measured as well as the relative...
-
2013
Major, Paul W., Melenka, Garrett W., Nobes, David S., Carey, Jason P.
The design and testing of an orthodontic torque simulator that reproduces the effect of archwire rotation on orthodontic brackets is described. This unique device is capable of simultaneously measuring the deformation and loads applied to an orthodontic bracket due to archwire rotation. Archwire...
-
2015
Melenka, Garrett W., Carey, Jason P.
The effect of short fiber reinforcements on the mechanical properties of cement has been examined using a splitting tensile – digital image correlation (DIC) measurement method. Three short fiber reinforcement materials have been used in this study: fiberglass, nylon, and polypropylene. The...
-
The Effect on Elastic Modulus of Rigid-Matrix Tubular Composite Braid Radius and Braid Angle Change Under Tensile Loading
Download2013
Melenka, Garrett W., Leung, Cheequn K., Nobes, David S., Carey, Jason P.
The objective of this paper is to assess changes in braid radius and braid angle of braided composite tubes under tensile loading using stereomicroscope digital image correlation (DIC) based optical measurement techniques. Using this approach, displacement fields were calculated and three...
-
2013
Carey, Jason P., Melenka, Garrett W., Nobes, David S., Major, Paul W.
Archwire rotation is used in orthodontic treatment to alter the labiolingual orientation of a tooth. Measurement of the 3-dimensional (3D) motion of the orthodontic brackets requires a new configuration of the orthodontic torque simulator. The orthodontic torque simulator was coupled with a...
-
2013
Nobes, David S., Major, Paul W., Melenka, Garrett W., Carey, Jason P.
Braces are used by orthodontists to correct the misalignment of teeth in the mouth. Archwire rotation is a particular procedure used to correct tooth inclination. Wire rotation can result in deformation to the orthodontic brackets, and an orthodontic torque simulator has been designed to examine...
-
Fall 2010
Deformation of the orthodontic bracket upon wire engagement may result in torque dissipation within the bracket rather than transmission to the tooth and its supporting structures. The purpose of this study was: 1) quantify the amount of torque expression and 2) quantify any deformation as a...