Search
Skip to Search Results- 16Carey, Jason
- 4Lepp, Eric
- 3Ead, Ahmed Samir
- 2Arce-Borkent, Alvaro
- 2Bennett, Kate
- 2Bruni-Bossio, Brianna
- 8WISEST Summer Research Program
- 8WISEST Summer Research Program/WISEST Research Posters
- 6Mechanical Engineering, Department of
- 5Mechanical Engineering, Department of/Journal Articles (Mechanical Engineering)
- 2Toolkit for Grant Success
- 2Toolkit for Grant Success/Educational Materials (Toolkit for Grant Success)
-
2007
Major, Paul, Carey, Jason, Russett, Shawn, Toogood, Roger, Boulanger, Pierre
Reproduction of anatomical structures by rapid prototyping has proven to be a valid adjunct for craniofacial surgery, providing alternative methods to produce prostheses and development of surgical guides. The aim of this study was to introduce a methodology to fabricate asymmetric human...
-
Clinical variability in arch wires: A preliminary study evaluating mechanical and surface characteristics of two different sized rectangular stainless steel wires
Download2007
Vena, Alessandro, Carey, Jason, Badawi, Hisham
Experimental characterization of arch wires has been performed in many previous studies; however with the advent of new arch wire materials being introduced, some new experimental methods and characterization are required. Since literature is available for comparison, this paper examines...
-
2014-01-01
Forst, Darren, Nijjar, Simrit, Flores-Mir, Carlos, Carey, Jason, Secanell, Marc, Lagravere, Manuel
The objective of this study is to analyze a set of previously developed and proposed image segmentation protocols for precision in both intra- and inter-rater reliability for in vivo tooth volume measurements using cone-beam computed tomography (CBCT) images. Six 3D volume segmentation procedures...
-
Density Conversion Factor Determined using a Cone-Beam Computed Tomography Unit NewTom QR-DVT 9000
Download2006
Carey, Jason, Lagravère, Manuel O., Major, Paul W., Fang, Y., Packota, Garnet V., Toogood, Roger W.
Objective: The purpose of this study was to determine a conversion coefficient for Hounsfield Units (HU) to material density (g cm−3) obtained from cone-beam computed tomography (CBCT-NewTom QR-DVT 9000) data. Methods: Six cylindrical models of materials with different densities were made and...
-
Effect of object location on the density measurement and hounsfield conversion in a NewTom 3G cone-beam computed tomography unit
Download2008
Ben-Zvi, Micha, Packota, Garnet V., Major, Paul W., Lagravère, Manuel O., Carey, Jason
Objectives: The purpose of this study was to determine the effect of an object's location in a cone beam CT imaging chamber (CBCT-NewTom 3G) on its apparent density and to develop a linear conversion coefficient for Hounsfield units (HU) to material density (g cm−3) for the NewTom 3G Scanner....