2020-10-15
Barta, Radim, Volotovskyy, Vyacheslav, Wachowicz, Keith, Fallone, B. Gino, De Zanche, Nicola
This is the peer reviewed version of the following article: Magn Reson Med. Early View, which has been published in final form at https://doi.org/10.1002/mrm.28540. This article may be used for non-commercial purposes in accordance with Wiley Terms and Conditions for Use of Self-Archived...
-
Impact of a Parallel Magnetic Field on Radiation Dose Beneath Thin Copper and Aluminum Foils
Download2020-04-10
Barta, Radim, Ghila, Andrei, Rathee, Satyapal, Fallone, B. Gino, De Zanche, Nicola
Purpose: The RF coils for magnetic resonance image guided radiotherapy (MRIgRT) may be constructed using thin and/or low-density conductors, along with thinner enclosure materials. This work measures the surface dose increases for lightweight conductors and enclosure materials in a magnetic field...