A Method for Standardizing MR Intensities between Slices and Volumes

  • Author(s) / Creator(s)
  • Technical report TR05-14. The first section of this paper describes a method for correcting inter-slice intensity variations in MR images. The method does not rely on a tissue model or segmentation, and is not affected by the presence of abnormalities. The second section of this work extends this technique to the correction of inter-volume intensity variations in MR images of the brain, using a characterization of bi-lateral symmetry to confer robustness to the presence of large abnormalities such as tumors or edema. | TRID-ID TR05-14

  • Date created
    2005
  • Subjects / Keywords
  • Type of Item
    Report
  • DOI
    https://doi.org/10.7939/R3R49GG8D
  • License
    Attribution 3.0 International