ERA

Download the full-sized PDF of Field Behavior of Steel Threaded Micropiles under Axial Loads in Cohesive SoilsDownload the full-sized PDF

Analytics

Share

Permanent link (DOI): https://doi.org/10.7939/R3QF8JX32

Download

Export to: EndNote  |  Zotero  |  Mendeley

Communities

This file is in the following communities:

Graduate Studies and Research, Faculty of

Collections

This file is in the following collections:

Theses and Dissertations

Field Behavior of Steel Threaded Micropiles under Axial Loads in Cohesive Soils Open Access

Descriptions

Other title
Subject/Keyword
foundation
field behavior
cohesive soil
micropiles
axial load
Type of item
Thesis
Degree grantor
University of Alberta
Author or creator
Guo, Zhengyang
Supervisor and department
Deng, Lijun
Examining committee member and department
Sego, Dave
Hendry, Michael
Deng, Lijun
Department
Department of Civil and Environmental Engineering
Specialization
Geotechnical Engineering
Date accepted
2017-04-25T15:56:22Z
Graduation date
2017-11:Fall 2017
Degree
Master of Science
Degree level
Master's
Abstract
Steel threaded micropiles are a new deep foundation system recently introduced to the piling industry of North America. This pile consists of a steel threaded tubular shaft that is tapered at the lower segment. Steel threaded micropiles are quick to install, easy to dismantle, and have been increasingly used to support new and existing structures. Therefore, it is important to study the performance of steel threaded micropiles installed in different soil types subject to various loading conditions. Although conventional micropiles have been investigated in a limited number of studies, there is not any study of the axial performance of steel threaded micropiles. Field tests of steel threaded full-scale micropiles with the diameter varying from 76 mm to 114 mm and length varying from 1.6 m to 3 m were carried out to investigate the axial bearing capacities, the load-transfer mechanism, the torque mechanism, and the axial cyclic response of the piles. Two cohesive soil sites were selected for the field tests: University of Alberta South Campus Site and Sherwood Park Site. Comprehensive site investigations including cone penetration tests (CPT), Shelby tube soil sampling, and laboratory tests were carried out for both sites. At the South Campus site, forty load tests were performed on piles subject to static axial compressive and tensile loads. Four test piles were instrumented with several strain gauge stations. Results showed the piles behave as frictional piles and reached the limit state before the displacement exceeded 10% of the pile diameter. The adhesion coefficient of the top smooth shaft at limit state was less than 0.1. The failure mode along the cylindrical threaded shaft was confirmed to be cylindrical shearing along the edge of the threads; the threads increased the axial capacities of the segment. Axial capacities of the threaded tapered segment were 43% on average greater than that of a cylindrical segment with the equivalent volume. Compressive capacities of all test piles were estimated based on preceding load-transfer mechanism and the results agreed reasonably well with the measured capacities. A theoretical torque model was proposed to estimate the end installation torques using the CPT-based remolded soil strength; the results matched the measured end torques very well. At the Sherwood Park site, twenty-five axial monotonic load tests and three axial cyclic load tests were performed. Three tests were instrumented with five strain gauge stations to investigate the unit shaft resistance development during the monotonic and cyclic loading. Results showed that the piles behave as frictional piles and skin friction is mobilized when the displacement reaches 5% to 10% of the pile diameter during monotonic load tests. With the similar installation torques, the compressive capacity of all test piles is greater than tensile capacity by an average of 27%. When subject to vertical earthquake loading, the steel threaded micropiles underwent acceptably small cumulative displacements of less than 2 mm. The magnitude of the cumulative displacement decreased with the pile length and pile diameter. Cyclic loading redistributed the load transfer along different segments of the pile and the negative skin friction was developed along the smooth pile shaft when the pile underwent decreasing axial loading. No degradation of pile axial stiffness was observed for the three piles tested under the range of applied cyclic loading.
Language
English
DOI
doi:10.7939/R3QF8JX32
Rights
This thesis is made available by the University of Alberta Libraries with permission of the copyright owner solely for the purpose of private, scholarly or scientific research. This thesis, or any portion thereof, may not otherwise be copied or reproduced without the written consent of the copyright owner, except to the extent permitted by Canadian copyright law.
Citation for previous publication
Guo, Z., and Deng, L. 2016a. Field investigation of the behavior of tapered screw piles. Annual Conf. Can. Geotech. Society, Vancouver, B.C., pp. 8.

File Details

Date Uploaded
Date Modified
2017-04-25T21:56:22.949+00:00
Audit Status
Audits have not yet been run on this file.
Characterization
File format: pdf (PDF/A)
Mime type: application/pdf
File size: 5549130
Last modified: 2017:06:13 12:15:34-06:00
Filename: Guo_Zhengyang_201704_MSc.pdf
Original checksum: 99dc272466525d50213863c80dd04ed7
Activity of users you follow
User Activity Date