ERA

Download the full-sized PDF of Separation and quantitation of apolipoprotein B48 and other apolipoproteins by dynamic sieving capillary electrophoresisDownload the full-sized PDF

Analytics

Share

Permanent link (DOI): https://doi.org/10.7939/R3FT8DZ35

Download

Export to: EndNote  |  Zotero  |  Mendeley

Communities

This file is in the following communities:

Agricultural, Food and Nutritional Science, Department of

Collections

This file is in the following collections:

Journal Articles (Agricultural, Food and Nutritional Science)

Separation and quantitation of apolipoprotein B48 and other apolipoproteins by dynamic sieving capillary electrophoresis Open Access

Descriptions

Author or creator
Proctor, Spencer D.
Mamo, John C. L.
Additional contributors
Subject/Keyword
Apolipoprotein B-48
Apolipoprotein Quantitation
Capillary Electrophoresis
Postprandial Lipoproteins
Chylomicrons
Type of item
Journal Article (Published)
Language
English
Place
Time
Description
Apolipoprotein-B-48 is a structural protein exclusively associated with post-prandial lipoproteins (chylomicrons). Apolipoprotein B-48 would be a useful marker to monitor the kinetics of chylomicrons in vivo, however, its quantitation is limited because of a low concentration in plasma and lack of specific antibodies. Dynamic sieving capillary electrophoresis (DSCE) has recently become widely available for the separation of nanomolar quantities of proteins by size and electrophoretic mobility. Here we describe the potential of DSCE to accurately quantitate apolipoprotein mass in one ml of plasma. Separation of human serum apolipoproteins was achieved through an uncoated fused silica glass capillary column with quantitation based on area response at 220 nm. The retention times of human apolipoprotein B-48, apolipoprotein B-100 and albumin were 8.96 min +/- 0.57%, 10.21 min +/- 0.72%, and 6.56 min +/- 0.4%, respectively (phase-standardized to internal reference). A significant correlation (r = 0.99) was observed between apolipoprotein concentrations and peak area response for mass ranges of 30-40 micrograms/ml. DSCE provides an alternative method for quantifying apolipoprotein B-48 and therefore, may be useful for studying postprandial lipoprotein metabolism.
Date created
1997
DOI
doi:10.7939/R3FT8DZ35
License information
© 1997 Spencer D. Proctor et al. This version of this article is open access and can be downloaded and shared. The original author(s) and source must be cited.
Rights

Citation for previous publication
Proctor, S. D., & Mamo, J. C. L. (1997). Separation and quantitation of apolipoprotein B48 and other apolipoproteins by dynamic sieving capillary electrophoresis. Journal of Lipid Research, 38(2), 410-414. Retrieved from:  http://www.jlr.org/content/38/2/410.short

Source

Link to related item

File Details

Date Uploaded
Date Modified
Audit Status
Audits have not yet been run on this file.
Characterization
File format: pdf (Portable Document Format)
Mime type: application/pdf
File size: 1059688
Last modified: 2017:09:06 16:30:00-06:00
Filename: JLR_38_2_410.pdf
Original checksum: 05cfd1a524b627a4d8f572c03859d730
Well formed: true
Valid: true
Page count: 5
Activity of users you follow
User Activity Date