Three-dimensional deformation of orthodontic brackets Open Access

Descriptions

Author or creator
Melenka, Garrett W.
Nobes, David S.
Major, Paul W.
Carey, Jason P.
Additional contributors
Subject/Keyword
Orthodontic Bracket
Stereo Microscope
Digital Image Correlation
Deformation
Archwire
Type of item
Journal Article (Published)
Language
English
Place
Time
Description
Braces are used by orthodontists to correct the misalignment of teeth in the mouth. Archwire rotation is a particular procedure used to correct tooth inclination. Wire rotation can result in deformation to the orthodontic brackets, and an orthodontic torque simulator has been designed to examine this wire–bracket interaction. An optical technique has been employed to measure the deformation due to size and geometric constraints of the orthodontic brackets. Images of orthodontic brackets are collected using a stereo microscope and two charge-coupled device cameras, and deformation of orthodontic brackets is measured using a three-dimensional digital image correlation technique. The three-dimensional deformation of orthodontic brackets will be evaluated. The repeatability of the three-dimensional digital image correlation measurement method was evaluated by performing 30 archwire rotation tests using the same bracket and archwire. Finally, five Damon 3MX and five In-Ovation R self-ligating brackets will be compared using this technique to demonstrate the effect of archwire rotation on bracket design.
Date created
2013
DOI
doi:10.7939/R3Q23RD15
License information
Attribution-NonCommerical-NoDerivs 3.0 Unported
Rights

Citation for previous publication
Melenka, G., Nobes, D., Major, P., and Carey, J. (2013). Three-dimensional deformation of orthodontic brackets. Journal of Dental Biomechanics, 4(0), 1758736013492529.
Source

Link to related item

File Details

Date Uploaded
Date Modified
Audit Status
Audits have not yet been run on this file.
Characterization
File format: pdf (Portable Document Format)
Mime type: application/pdf
File size: 1667226
Last modified: 2017:09:05 16:25:30-06:00
Filename: JDB_4_0_1758736013492529.pdf
Original checksum: cb7f20f877b25beb2d726098cf8a9202
Well formed: true
Valid: true
Page count: 15
Activity of users you follow
User Activity Date