Effect of object location on the density measurement and hounsfield conversion in a NewTom 3G cone-beam computed tomography unit Open Access

Descriptions

Author or creator
Lagravère, Manuel O.
Carey, Jason
Ben-Zvi, Micha
Packota, Garnet V.
Major, Paul W.
Additional contributors
Subject/Keyword
Hounsfield Value
Computed Tomography
Bone Density
Type of item
Journal Article (Published)
Language
English
Place
Time
Description
Objectives: The purpose of this study was to determine the effect of an object's location in a cone beam CT imaging chamber (CBCT-NewTom 3G) on its apparent density and to develop a linear conversion coefficient for Hounsfield units (HU) to material density (g cm−3) for the NewTom 3G Scanner. Methods: Three cylindrical models of materials with different densities were constructed and scanned at five different locations in a NewTom 3G Volume Scanner. The average HU value for each model at each location was obtained using two different types of software. Next, five cylinders of different known densities were scanned at the exact centre of a NewTom 3G Scanner. The collected data were analysed using the same two types of software to determine a standard linear relationship between density and HU for each type of software. Results: There is no statistical significance of location of an object within the CBCT scanner on determination of its density. A linear relationship between the density of an object and the HU of a scan was ρ = 0.001(HU)+1.19 with an R2 value of 0.893 (where density, ρ, is measured in g cm−3). This equation is to be used on a range between 1.42 g cm−3 and 0.4456 g cm−3. Conclusions: A linear relationship can be used to determine the density of materials (in the density range of bone) from the HU values of a CBCT scan. This relationship is not affected by the object's location within the scanner itself.
Date created
2008
DOI
doi:10.7939/R3377680X
License information

Rights
© 2008 Manuel O. Lagravère et al. This version of this article is open access and can be downloaded and shared. The original author(s) and source must be cited.
Citation for previous publication
Lagravère, M., Carey, J., Ben-Zvi, M., Packota, G., and Major, P. (2008). Effect of object location on the density measurement and hounsfield conversion in a NewTom 3G cone-beam computed tomography unit. Dentomaxillofacial Radiology, 37(6), 305-308.
Source

Link to related item

File Details

Date Uploaded
Date Modified
Audit Status
Audits have not yet been run on this file.
Characterization
File format: pdf (Portable Document Format)
Mime type: application/pdf
File size: 95876
Last modified: 2017:09:05 16:25:01-06:00
Filename: DMR_37_6_305.pdf
Original checksum: f8f6d6bbbd21ee7e9952b8e450db81f9
Well formed: true
Valid: true
File title: untitled
Page count: 4
Activity of users you follow
User Activity Date