ERA

Download the full-sized PDF of Multi-Objective Optimization Framework for Landmark Measurement Error Correction in Three Dimensional Cephalometric TomographyDownload the full-sized PDF

Analytics

Share

Permanent link (DOI): https://doi.org/10.7939/R3BR8MV83

Download

Export to: EndNote  |  Zotero  |  Mendeley

Communities

This file is in the following communities:

Mechanical Engineering, Department of

Collections

This file is in the following collections:

Journal Articles (Mechanical Engineering)

Multi-Objective Optimization Framework for Landmark Measurement Error Correction in Three Dimensional Cephalometric Tomography Open Access

Descriptions

Author or creator
DeCesare, Alessandro
Secanell, Marc
Lagravère, Manuel O.
Carey, Jason P.
Additional contributors
Subject/Keyword
Orthodontics
Landmark Optimization Procedure
Maxillary Expansion Treatment
Cone Beam Computed Tomography
Type of item
Journal Article (Published)
Language
English
Place
Time
Description
The purpose of this study is to minimize errors that occur when using a four vs six landmark superimpositioning method in the cranial base to define the co-ordinate system. Cone beam CT volumetric data from ten patients were used for this study. Co-ordinate system transformations were performed. A co-ordinate system was constructed using two planes defined by four anatomical landmarks located by an orthodontist. A second co-ordinate system was constructed using four anatomical landmarks that are corrected using a numerical optimization algorithm for any landmark location operator error using information from six landmarks. The optimization algorithm minimizes the relative distance and angle between the known fixed points in the two images to find the correction. Measurement errors and co-ordinates in all axes were obtained for each co-ordinate system. Significant improvement is observed after using the landmark correction algorithm to position the final co-ordinate system. The errors found in a previous study are significantly reduced. Errors found were between 1 mm and 2 mm. When analysing real patient data, it was found that the 6-point correction algorithm reduced errors between images and increased intrapoint reliability. A novel method of optimizing the overlay of three-dimensional images using a 6-point correction algorithm was introduced and examined. This method demonstrated greater reliability and reproducibility than the previous 4-point correction algorithm.
Date created
2013
DOI
doi:10.7939/R3BR8MV83
License information

Rights
© 2013 Alessandro DeCesare et al. This version of this article is open access and can be downloaded and shared. The original author(s) and source must be cited.
Citation for previous publication
DeCesare, A., Secanell, M., Lagravère, M., and Carey, J. (2013). Multi-Objective Optimization Framework for Landmark Measurement Error Correction in Three Dimensional Cephalometric Tomography. Dentomaxillofacial Radiology, 42(7), 20130035 (10 pages).
Source

Link to related item

File Details

Date Uploaded
Date Modified
Audit Status
Audits have not yet been run on this file.
Characterization
File format: pdf (Portable Document Format)
Mime type: application/pdf
File size: 845103
Last modified: 2017:09:05 16:24:49-06:00
Filename: DMR_42_7_20130035.pdf
Original checksum: dd04967a634e505bc273fb14a6e28a1b
Well formed: true
Valid: false
Status message: Invalid destination object offset=835597
Status message: Invalid destination object offset=835597
Status message: Invalid destination object offset=835597
Status message: Invalid destination object offset=835597
Status message: Invalid destination object offset=835597
File title: DMFRD13035 1..10
Page count: 10