Structural Reliability of Non-Slender Loadbearing Concrete Masonry Members under Concentric and Eccentric Loads Open Access

Descriptions

Other title
Subject/Keyword
Concrete
Reliability
Masonry
Type of item
Thesis
Degree grantor
University of Alberta
Author or creator
Moosavi Nanehkaran, Seyed Abdol Hadi
Supervisor and department
Adeeb, Samer (Civil & Environmental Engineering)
Korany, Yasser (Civil & Environmental Engineering)
Examining committee member and department
Tomlinson, Douglas (Civil & Environmental Engineering)
Lissel, Shelley (Civil & Environmental Engineering, University of Calgary)
Cruz Noguez, Carlos (Civil & Environmental Engineering)
El-Rich, Marwan (Civil & Environmental Engineering)
Department
Department of Civil and Environmental Engineering
Specialization
Structural Engineering
Date accepted
2017-09-29T14:18:27Z
Graduation date
2017-11:Fall 2017
Degree
Doctor of Philosophy
Degree level
Doctoral
Abstract
Although the reliability levels of structural steel and reinforced concrete structures designed to the Canadian codes and standards have been investigated substantially in the past four decades, studies on the reliability of masonry structures are limited. Based on some preliminary studies in 1980s, the design of masonry structures using the limit states method was introduced in the 1994 edition of the Canadian standard S304 in order to provide more uniform and economical design guidelines. However, the limit states design criteria were not supported by a rigorous reliability-based analysis. The investigation reported herein was carried out to contribute to filling the gap in our knowledge on the reliability of structural masonry members designed using the limit states method, to establish reliability levels for masonry comparable to other structural materials and to help remove any unnecessary conservatism in the masonry design process. The first order reliability method was used to assess the reliability of unreinforced and reinforced non-slender concrete masonry walls under combined axial load and out-of-plane bending. In this research, only non-slender walls having a slender ratio (kh/t) not requiring consideration of second order effects are considered. Nevertheless, the procedure for performing the reliability analysis for walls with larger kh/t is proposed and explained.
Language
English
DOI
doi:10.7939/R3F18SV2Z
Rights
This thesis is made available by the University of Alberta Libraries with permission of the copyright owner solely for the purpose of private, scholarly or scientific research. This thesis, or any portion thereof, may not otherwise be copied or reproduced without the written consent of the copyright owner, except to the extent permitted by Canadian copyright law.
Citation for previous publication

File Details

Date Uploaded
Date Modified
2017-09-29T20:18:28.086+00:00
Audit Status
Audits have not yet been run on this file.
Characterization
File format: pdf (PDF/X)
Mime type: application/pdf
File size: 12845112
Last modified: 2017:11:08 18:26:44-07:00
Filename: Dissertation A.pdf
Original checksum: 6d94569dda5a748f71038653fe80d905
Activity of users you follow
User Activity Date